Glass Lined "Shell in Shell Type" Condenser & Heat Exchanger
Construction
Glass Lined from Outside and Jacketed from inside Pan is Assembled in Glass Lined from inside and Jacketed from Outside Pan Forming Shell in Shell Condenser/Heat Exchanger. Heat Exchanger areawise Dimensions will be as Indicated Herein.
Maximum Allowable Operating Conditions
Process Conditions | Inner Vessel | Jacket Space |
Maximum Allowable Working Pressure | Full Vacuum To 3 Kg/cm²(G) | 3 Kg/cm²(G) |
Design Temperature | -25 To 200° C | -25 To 200° C |
Condensers Suitable to Higher Temperature and Pressure can be Supplied on Request.
Nozzle Connection:
- Process Side : Split Flanges Drilled in Accordance with PN10 /
ANSIB16.5 150# - Jacket Side : Integral SORF in Accordance with ANSIB16.5 150#
Support :
- Side Brackets (Standard)
- Side Brackets with Legs (Optional – on Request)
“Shell in Shell” Type Condenser and Heat Exchanger | ||||||
Area | Sq. Mtr. | 2 | 4 | 6 | 8 | 10 |
D1 | 219.1 | 400 | 500 | 650 | 650 | |
D2 | 323.8 | 500 | 600 | 750 | 750 | |
D3 | 406.4 | 600 | 700 | 850 | 850 | |
D4 | 508 | 700 | 800 | 950 | 950 | |
D5 | 674 | 956 | 1055 | 1230 | 1230 | |
Dimensions | H1 | 1150 | 1600 | 1900 | 2050 | 2450 |
H2 | 140 | 160 | 182 | 200 | 200 | |
H3 | 450 | 850 | 900 | 1050 | 1450 | |
H4 | 200 | 250 | 250 | 275 | 275 | |
H | 1300 | 1770 | 2092 | 2260 | 2660 | |
Nozzles | N1 | 100 | 150 | 150 | 200 | 250 |
N2 | 50 | 50 | 80 | 80 | 80 | |
N3 | 25 | 25 | 40 | 50 | 50 | |
N4 | 25 | 25 | 40 | 50 | 50 | |
N5 | 25 | 25 | 40 | 50 | 50 | |
N6 | 25 | 25 | 40 | 50 | 50 | |
Approx. Weight | Kg | 550 | 1000 | 1500 | 2010 | 2330 |
All Dimensions are in mm Unless Otherwise Specified |