Glass Lined Plate Type Condenser & Heat Exchanger
Construction
Jacketed Glassed Steel Disc Modules Clamped Together form Heat Exchanger/Condenser Assembly. Process Side in Assembly is Glassed Steel Enabling Condensation, Cooling and Heating of Corrosive Process Fluids. Heat Exchanger Area wise Dimensions will be as Indicated Herein.
Maximum Allowable Operating Conditions
Process Conditions | Inner Vessel | Jacket Space |
Maximum Allowable Working Pressure | Full Vacuum To 3 Kg/cm²(G) | 3 Kg/cm²(G) |
Design Temperature | -25 To 200° C | -25 To 200° C |
Condensers Suitable to Higher Temperature and Pressure can be Supplied on Request.
Nozzle Connection:
• Process Side : Split Flanges Drilled in Accordance with PN10 / ANSIB16.5 150#
• Jacket Side : Integral SORF in Accordance with ANSIB16.5 150#
Support :
• Side Brackets (Standard)
• Side Brackets with Legs (Optional – on Request)
Disc Condenser & Heat Exchanger | |||||||||
Heat Transfer Area Sq. Mtr. | Inner Vessel Volume (Ltrs.) | Jacket Volume (Ltrs.) | ØD | H1 | H | Nozzles | |||
Jacket Inlet | Jacket Outlet | Process Inlet | Condensate Drain | ||||||
2 | 200 | 255 | 820 | 1157 | 1317 | 40 | 40 | 80 | 80 |
4 | 400 | 450 | 1020 | 1350 | 1510 | 50 | 50 | 100 | 100 |
6 | 510 | 600 | 1020 | 1705 | 1865 | 50 | 50 | 100 | 100 |
8 | 850 | 1100 | 1200 | 2013 | 2173 | 50 | 50 | 100 | 100 |
10 | 1200 | 1150 | 1400 | 1880 | 2080 | 50 | 50 | 150 | 150 |
All Dimensions are in mm unless otherwise specified |